Battery comparison types
14 messages · 6 photos · click a photo to enlarge it
All three—conventional lead-acid, AGM, and gel—are lead-acid batteries. They use essentially the same chemistry, but differ in how the sulfuric acid electrolyte is contained inside the battery. This affects starting current, charging requirements, durability, and maintenance.
1. Physical construction
Conventional (Flooded)
Liquid sulfuric acid surrounds the lead plates.
AGM
Acid is absorbed into fiberglass mats between the lead plates.
Gel
Acid is mixed with silica to form a thick gel.
2. Performance comparison
Characteristic |
Flooded |
AGM |
Gel |
|---|---|---|---|
Electrolyte |
Free liquid |
Absorbed liquid |
Gel |
Starting current (CCA) |
Good |
Excellent |
Generally lower |
Internal resistance |
Moderate |
Very low |
Generally higher than AGM |
Charging speed |
Moderate |
Fast |
Slower |
Vibration resistance |
Moderate |
Excellent |
Very good |
Spill resistance |
Poor |
Excellent |
Excellent |
Maintenance |
Sometimes required |
None |
None |
Self-discharge |
Higher |
Low |
Low |
Deep discharge tolerance |
Fair |
Good* |
Excellent* |
Cold-weather starting |
Good |
Excellent |
Generally lower |
Overcharging tolerance |
Moderate |
Limited |
Very limited |
Relative cost |
$ |
$$ |
$$$ |
Motorcycle starting |
Good |
Excellent |
Fair |
*Deep discharge tolerance also depends on whether the battery is designed for starting or deep-cycle applications.
3. Voltage and charging characteristics
Typical voltages for a 12 V battery at approximately 25°C:
Condition |
Flooded |
AGM |
Gel |
|---|---|---|---|
Fully charged, resting |
12.6–12.8 V |
12.8–13.0 V |
12.7–12.9 V |
Absorption charging |
14.4–14.8 V |
14.4–14.8 V |
14.1–14.4 V |
Float charging |
13.2–13.5 V |
13.5–13.8 V |
13.5–13.8 V |
These are typical ranges. The individual battery manufacturer’s specifications take precedence.
Gel batteries are particularly sensitive to excessive charging voltage, which can create permanent voids in the gel electrolyte.
4. Internal resistance and starter motor performance
AGM’s biggest advantage for motorcycles is its low internal resistance.
When the starter motor draws a large current, the battery terminal voltage drops according to:
Here is an interactive example showing how internal resistance affects a battery during cranking.
Battery Voltage Under Starter Load
Open-circuit battery voltage: 12.80 V
Vterminal = Voc − I × R
Resistance is converted from milliohms to ohms.
Battery Voltage vs. Internal Resistance
Open-circuit battery voltage: 12.85 V
Simplified equivalent-circuit model assuming constant starter current. Actual current varies with battery voltage, motor speed and engine load. Voltage thresholds are illustrative, not BMW factory specifications.
5. Relevance to your 2022 BMW R1250GS
Considering the starting problem you described yesterday, where the starter cranks for half a second and then the dashboard reboots, the battery type and internal resistance are particularly important.
Your new battery is rated at 12 V, 17 Ah, and 200 CCA.
These three specifications tell you different things:
-
12 V: Nominal operating voltage.
-
17 Ah: Energy storage capacity, expressed as charge capacity.
-
200 CCA: Cold-cranking current capability under standardized test conditions.
-
Internal resistance: Determines how much voltage collapses under a heavy electrical load.
A battery can display 12.8 V at rest and still have insufficient cranking performance.
For your BMW motorcycles, I would generally favor a high-quality AGM starting battery that meets or exceeds BMW’s specified cranking requirements.
Before replacing the new battery again, I would measure the minimum voltage directly across its battery posts during both a successful start and a failed start. I would also check voltage drop across the positive battery cable and engine ground connection.
The dashboard reboot is consistent with a momentary supply-voltage collapse, but it does not necessarily mean the battery itself is defective. A poor connection, excessive starter current, or high cable resistance could produce the same symptoms. I would not rule out any of these yet.
These two measurements are very useful in diagnosing the starting problem on your 2022 BMW R1250GS. The battery passes the ICON T10 battery test, but the oscilloscope waveform shows a substantial voltage collapse during cranking.
I would not consider the battery or starter motor cleared of suspicion yet.
1. ICON T10 battery test
Battery test results
12.85 V
12.20 mΩ
199 A
200 A
100%
100%
The battery appears fully charged and meets its advertised CCA rating according to the tester. However, the T10 estimates cranking capability electronically; it does not necessarily reproduce the actual load imposed by the BMW starter motor.
The 12.20 milliohm internal resistance is particularly useful for our investigation.
2. Oscilloscope waveform analysis
Your Tektronix TDS3012B is set to:
-
Vertical scale: 2 V/division
-
Horizontal scale: 400 ms/division
-
Trigger level: 12.0 V
Using the yellow channel reference marker on the left and the vertical scale, I estimate the following waveform:
~6.0 V
~6.8 V
~650 ms
~14 V
The 8.40 V cursor reading in the upper right of your oscilloscope is not the minimum voltage of the waveform.
The minimum appears to be approximately 6 V, assuming DC coupling and zero vertical offset. This is sufficiently low to potentially cause the dashboard and other electronic modules to reboot.
The recovery to approximately 14 V suggests that this particular capture may be from a successful start.
3. Calculate the estimated starter current
Using your measured battery internal resistance:
That is a very substantial estimated instantaneous current. However, the T10’s measured internal resistance may differ from the battery’s effective resistance during actual cranking, so this is not a verified current measurement.
Starter current |
Calculated battery voltage |
|---|---|
100 A |
11.63 V |
150 A |
11.02 V |
200 A |
10.41 V |
250 A |
9.80 V |
300 A |
9.19 V |
350 A |
8.58 V |
400 A |
7.97 V |
500 A |
6.75 V |
560 A |
6.02 V |
- 0: Calculated battery voltage 12.9 V
- 100: Calculated battery voltage 11.6 V
- 200: Calculated battery voltage 10.4 V
- 300: Calculated battery voltage 9.2 V
- 400: Calculated battery voltage 8 V
- 500: Calculated battery voltage 6.8 V
- 560: Calculated battery voltage 6 V
- 600: Calculated battery voltage 5.5 V
4. What could be causing this?
Possible cause |
My assessment |
|---|---|
Insufficient battery cranking capability |
High suspicion |
Excessive battery internal resistance under load |
High suspicion |
Excessive starter motor current |
High suspicion |
Excessive mechanical resistance in engine |
Possible |
Decompression mechanism problem |
Possible |
Battery cable or ground resistance |
Still worth checking |
Defective starter relay |
Lower suspicion |
Defective ECU |
Lower suspicion |
Defective dashboard |
Lower suspicion |
Because you measured directly across the battery terminals, we now know that the voltage collapse occurs at the battery itself. A poor connection elsewhere could contribute to the starting problem, but would not ordinarily explain this magnitude of battery terminal voltage collapse by itself.
5. Next test: simultaneously measure voltage and current
Your two-channel Tektronix oscilloscope is ideal for this investigation.
Use Channel 1 for battery voltage and Channel 2 for starter current. Use an appropriate isolated current probe, and keep the oscilloscope’s voltage probe ground connected to battery negative.
Record the following conditions:
Test |
Min. voltage |
Peak current |
Result |
|---|---|---|---|
First cold start |
|||
Immediate second start |
|||
Immediate third start |
|||
Failed start with dashboard reboot |
|||
Restart after 15-second recovery |
This will help differentiate between a battery that cannot deliver sufficient current and a starter that is demanding excessive current.
6. Another simple diagnostic test
Before purchasing any additional test equipment, you could temporarily connect a known-good, fully charged automotive 12 V battery in parallel with the motorcycle battery, with the automobile engine OFF, following the BMW jump-start procedure.
Then repeat the sequence of successive starts.
If the problem disappears, that strongly suggests insufficient electrical supply capability from the motorcycle battery, although excessive starter current could still be contributing.
If the problem persists, I would concentrate on measuring starter current and investigating the starter and mechanical starting load.
7. One important question
Was this oscilloscope waveform recorded during a successful start, or during the failed start when the dashboard rebooted?
If this is a successful start and the voltage is already dropping to approximately 6 V, there may be very little operating margin left for the motorcycle’s electronic systems. Comparing the successful and failed start waveforms would be particularly revealing.
This second oscilloscope capture is much more revealing. During the unsuccessful start, the battery voltage appears to collapse to approximately 4.8 V and remain there for about 800 milliseconds.
That is a severe voltage collapse, and it readily explains why the dashboard reboots. More importantly, the shape of the waveform is substantially different from the successful start.
1. Successful versus unsuccessful start
Measurement |
Successful start |
Failed start |
|---|---|---|
Initial battery voltage |
12.85 V |
~12.8 V |
Minimum battery voltage |
~6 V |
~4.8 V |
Voltage during cranking |
Fluctuating and recovering |
Drops and remains low |
Sustained severe voltage drop |
No |
~800 ms |
Voltage after cranking |
~14 V |
~12.8 V |
Engine starts |
Yes |
No |
The voltages and durations are approximate readings from your oscilloscope photographs.
Comparison of the two starting waveforms
2. The flat portion of the waveform is particularly interesting
Notice the three distinct phases of the failed start:
-
Phase A: Initial starter engagement and voltage drop.
-
Phase B: Voltage partially recovers and fluctuates, suggesting that the starter and engine are initially rotating.
-
Phase C: Voltage drops to 4.8 V and remains remarkably constant until the starter is disengaged.
Phase C is consistent with a stalled or nearly stalled starter motor.
As a DC motor slows down, its back EMF decreases. If the motor stops rotating, its current is limited primarily by the circuit resistance.
When the motor stalls, the back EMF approaches zero.
This could explain both the magnitude and the relatively flat shape of the voltage drop. However, we need a current measurement to confirm this interpretation.
3. Equivalent circuit during the suspected stall
Using the T10 internal resistance value:
The corresponding external circuit resistance would be:
660 A is an inferred current, not a measured current. The battery’s dynamic internal resistance under heavy load could be substantially different from the T10 reading.
4. Possible causes, in order of investigation
Possible cause |
Priority |
|---|---|
Battery has insufficient cranking capability |
Very high |
Starter stalls at engine compression stroke |
Very high |
Defective starter motor |
High |
Automatic decompression mechanism problem |
Worth investigating |
Defective battery despite passing T10 test |
High |
Battery cable or ground connection |
Medium |
Starter relay failure |
Lower |
ECU or dashboard failure |
Lower |
I am particularly interested in the possibility that the engine reaches a compression stroke, the starter cannot overcome it, the motor stalls, and the battery voltage collapses.
5. What I would test next
Test 1 — Use a larger external battery.
Connect a known-good automotive 12 V battery in parallel, with the automobile engine off, following BMW’s jump-start procedure. Repeat the successive starting sequence that normally produces the failure.
Test 2 — Capture starter current.
Use a DC Hall-effect current probe with at least a 1,000 A measurement range and connect it to Channel 2 of your Tektronix. Continue measuring battery voltage with Channel 1.
Test 3 — Measure dynamic battery internal resistance.
With simultaneous voltage and current measurements, you can calculate the effective battery internal resistance during the actual starting event:
This would be more informative for this particular problem than the T10 test.
Test 4 — Read BMW fault codes.
Your GS-911 may be able to identify undervoltage faults, module resets or starter-related faults. Save the fault report before clearing anything.
6. Recommended oscilloscope settings
For the next capture:
Setting |
Recommended value |
|---|---|
CH1 vertical scale |
2 V/div |
CH1 coupling |
DC |
CH2 |
DC current probe |
Timebase |
200 ms/div |
Trigger source |
CH1 |
Trigger slope |
Falling |
Trigger level |
10 V |
Acquisition |
Single sequence |
Pre-trigger |
20% |
Vertical position |
Display approximately 0–16 V |
The 10 V/division setting in your second photograph sacrifices considerable voltage resolution.
My current conclusion
The dashboard reboot is almost certainly a consequence of the voltage collapse rather than the primary cause of the starting problem.
What remains to be determined is whether the battery is inadequate for the starter load, or the starter load is abnormally high.
The sustained 4.8 V plateau makes the possibility of starter motor stall particularly worth investigating. I would perform the external battery test next, before purchasing any replacement components.
This is a significant improvement. The booster pack substantially reduces the voltage drop during starting.
Your clarification that the engine stopped rotating while the starter button was still depressed, with the battery voltage remaining at 4.8 V, is also important. It strengthens the possibility that the starter was stalled while still drawing current.
1. Comparison of all three tests
Minimum battery terminal voltage
Battery only – failed start
~4.8 V
Battery only – successful start
~6.0 V
Battery + booster – successful start
~7.8 V
Parameter |
Successful, battery only |
Failed, battery only |
With booster |
|---|---|---|---|
Initial voltage |
12.85 V |
~12.8 V |
~12.3 V |
Minimum voltage |
~6.0 V |
~4.8 V |
~7.8 V |
Initial voltage drop |
~6.85 V |
~8.0 V |
~4.5 V |
Sustained stall |
No |
Suspected |
No |
Charging voltage |
~14 V |
N/A |
~14.5 V |
Even with the booster pack, the voltage drop is substantial.
2. Comparison of the waveform shapes
3. What happens when the engine stops rotating?
There are two very different electrical conditions:
Condition |
Starter current |
Battery voltage |
|---|---|---|
Starter relay opens |
Falls toward zero |
Recovers immediately |
Starter motor stalls with relay closed |
Remains high |
Remains depressed |
Battery develops an internal fault |
May vary |
May remain depressed |
Your observation of a sustained 4.8 V after rotation stopped is more consistent with the second condition than the first.
It also suggests that the ECU may not be deliberately stopping the starter initially. The starter may simply be unable to develop sufficient torque to continue turning the engine.
4. Battery equivalent circuit with booster
The booster pack is effectively reducing the source impedance available to the starter motor.
However, we still cannot determine whether the original battery has excessive impedance or the starter is drawing excessive current.
5. What I would do next
Test |
Purpose |
|---|---|
Perform several successive starts with the booster connected |
Determine whether the fault disappears |
Measure starter current with a DC current clamp |
Identify excessive current or a locked-rotor condition |
Measure voltage directly across the battery posts |
Eliminate terminal contact resistance from the measurement |
Measure battery negative to starter housing voltage drop |
Check engine grounding |
Measure battery positive to starter positive voltage drop |
Check cables and relay contacts |
Test with a known-good, higher-CCA AGM battery |
Eliminate the existing battery as the cause |
Investigate the starter and decompression mechanism |
Determine whether abnormal mechanical load exists |
Avoid intentionally holding the starter in a stalled condition. Release the button as soon as rotation stops, because the sustained current could damage the starter, relay, battery or cables.
6. My current assessment
I am increasingly suspicious of three things:
-
Insufficient cranking capability of the new 200 CCA battery.
-
Excessive starter motor current.
-
Excessive mechanical resistance when the engine reaches a compression stroke.
The battery passing the T10 test does not eliminate the first possibility.
I would not replace the ECU or starter relay based on the evidence so far.
With the booster pack connected, were you able to repeatedly start and stop the motorcycle without reproducing the failure?
That is the most important remaining question from this particular test.
That is a very important diagnostic result. The fact that you cannot reproduce the starting failure with the booster pack connected strongly suggests that insufficient available starting power is central to the problem.
The new 200 CCA battery is now my primary suspect, although excessive starter current or mechanical resistance could still be contributing.
Here is what we have established:
Test |
Result |
|---|---|
Battery resting voltage |
12.85 V — good |
T10 battery health |
100% — passes |
Battery internal resistance |
12.2 mΩ |
Battery-only successful start |
Drops to approximately 6 V |
Battery-only failed start |
Sustained 4.8 V |
Battery with booster |
Approximately 7.8 V minimum |
Repeated starts with booster |
All successful |
I would now investigate whether the installed battery meets the original BMW battery specifications before removing the starter motor or investigating the decompression mechanism.
Recommended replacement battery
I checked Yuasa’s application guide for the 2022 R1250GS. These three AGM batteries are listed as compatible replacements.
Battery |
Capacity |
CCA |
|---|---|---|
Your current battery |
17 Ah |
200 A |
Yuasa YTX14-BS |
12 Ah |
200 A |
Yuasa YTX14H-BS |
12 Ah |
240 A |
Yuasa GYZ16H |
16 Ah |
240 A |
The Yuasa GYZ16H would be my preferred replacement to evaluate, subject to confirming physical dimensions and terminal placement.
Note that 200 CCA is not necessarily an incorrect rating for this motorcycle. I have confirmed aftermarket compatibility, but not the exact original BMW battery’s CCA specification.
One more diagnostic test before buying a battery
I would like to measure the voltage across the battery and starter current simultaneously.
If you don’t have a suitable DC current probe, another option is to temporarily substitute a known-good, fully charged battery rather than adding the booster in parallel.
Then compare the results:
Result |
Likely interpretation |
|---|---|
Voltage remains above approximately 10 V and all starts succeed |
Original battery likely inadequate under load |
Voltage still drops below 8 V |
Investigate excessive starter load |
Starter current remains high after rotation stops |
Starter stall or mechanical resistance |
Starter current stops but voltage remains low |
Investigate battery or another electrical load |
These voltage thresholds are diagnostic guidelines, not verified BMW specifications.
What battery did you install?
Can you send me the manufacturer and model number, or a photograph of the battery label?
I particularly want to determine:
-
Whether it is AGM, gel or conventional lead-acid.
-
Its specified CCA test standard.
-
Whether it is designed specifically for engine starting.
-
Whether its manufacturer lists compatibility with the R1250GS.
The fact that your battery is rated at 17 Ah but only 200 CCA makes me interested in its construction.
At this point, I would leave the ECU, starter relay and starter motor alone until we have eliminated the battery as the source of the problem.
The battery label reveals two important details that clarify our investigation.
This is an Xtreme XTAX14L-BS AGM battery, and its capacity is 12 Ah, not 17 Ah as we previously understood.
Specification |
Battery label / test results |
|---|---|
Manufacturer/brand |
Xtreme |
Model |
XTAX14L-BS |
Battery chemistry |
AGM lead-acid |
Nominal voltage |
12 V |
Capacity |
12 Ah |
Tested CCA |
200 A |
Measured internal resistance |
12.2 mΩ |
Distributor |
Ascent Battery Supply, LLC |
It is already an AGM battery, so the issue is not that you installed a conventional flooded or gel battery.
I’ll compare this specific model with the recommended battery for the 2022 R1250GS, including terminal orientation.
1. BMW’s original battery specification
According to the BMW R1250GS rider’s manual, the standard battery specification is 12 V, 14 Ah, maintenance-free AGM.
Your Xtreme battery has a lower capacity than the BMW specification.
Yuasa lists the following replacement batteries for the 2019–2022 R1250GS.
Battery |
Capacity |
CCA |
|---|---|---|
Installed Xtreme XTAX14L-BS |
12 Ah |
200 A (tested) |
BMW original specification |
14 Ah |
Not verified |
Yuasa YTX14-BS |
12 Ah |
200 A |
Yuasa YTX14H-BS |
12 Ah |
240 A |
Yuasa GYZ16H |
16 Ah |
240 A |
I could not locate an authoritative specification sheet for your exact Xtreme battery, so its manufacturer’s CCA rating remains unverified.
2. Terminal orientation
There is another important difference: the L in your battery’s model number generally indicates reversed terminal orientation compared with the corresponding non-L Yuasa model.
Your battery
Standard non-L configuration
This does not explain the starting failure if the battery is correctly connected, but it is important when ordering a replacement. Confirm the case dimensions, cable reach and physical terminal orientation.
3. How much difference would a lower internal resistance make?
Using your measured 12.2 mΩ as a starting point, we can model the effect of different battery internal resistances.
Battery voltage versus internal resistance
Assuming a 12.85 V open-circuit voltage and a fixed starter current.Starter current
400 A
12.2 mΩ (Xtreme)
7.97 V
10.0 mΩ
8.85 V
8.0 mΩ
9.65 V
6.0 mΩ
10.45 V
4.0 mΩ
11.25 V
This is why I am more interested in the internal resistance and actual cranking performance than the Ah rating alone.
4. My recommendation
I would consider exchanging the Xtreme battery for a higher-performance AGM battery, preferably the Yuasa GYZ16H, 16 Ah, 240 CCA, provided the terminal orientation and dimensions are correct.
Before installing the replacement:
-
Fully charge it using an AGM-compatible charger.
-
Measure its internal resistance using your ICON T10.
-
Record its resting voltage and measured CCA.
-
Install it and repeat the oscilloscope measurements.
-
Perform the same successive starting sequence.
If the new battery also drops to 6–8 V during starting, I would investigate the starter motor current and engine decompression mechanism.
The booster pack experiment has already demonstrated that increasing the available starting power eliminates the observed failure. We still need to establish whether the battery is underperforming or the starter is demanding more current than it should.
I’ve created a Work conversation to prepare a complete, printable PDF of this chat, including:
-
All questions and responses, in chronological order.
-
All six original photographs, including the oscilloscope captures, battery tester results and battery label.
-
Electrical schematics, comparison graphs and tables.
-
Calculations, diagnostic conclusions and recommended troubleshooting procedures.
I’ve requested US Letter (8.5 × 11 inches) formatting, with interactive graphics converted to printable versions where possible.
This will be a full conversation transcript, not a condensed troubleshooting report. The PDF itself has not yet been generated or verified in this chat.
Leave a Reply